Accueil > Votre activité > Nucléaire
Nucléaire
|
|
|
|
High temperature thermal analysis is a key technique in several steps of the nuclear fuel cycle. Studies of sintering of uranium oxide powder, corrosion behaviour of the Zircalloy employed to seal UO2, or design of materials used in the reactor vessel (which are exposed to high temperature). Moreover, the thermal activity of different kind of wastes, immersed in bitumen, concrete, glass or other ceramic based matrixes can be measured by our high sensitivity, high volume calorimeters.
|
![]() |
|
The application of the SETARAM instruments include: - Uranium conversion and enrichment - high temperature corrosion - zircalloy reactivity - stability of treated wastes |
|
| Brochure | |
High Sensitivity air bath Calorimeter for Non Destructive Assay of 3013 containers |
||
|
LVC-3013The SERIES 3013 is a high sensitive twin cells calorimeter designed for the characterization of nuclear materials and more particularly for the analysis of radioactive wastes and quantification of radioactive elements (e.g. curium, plutonium, tritium) contained in shielded 3013 containers. See more. |
|
High Sensitivity Large Volume 15 Liters Calorimeter for Non Destructive Assay |
||
|
LVC-270-3WThe Series 270 is a high sensitive twin cells calorimeter designed for the characterization of nuclear materials and more particularly for the analysis of radioactive wastes and quantification of radioactive elements (e.g. curium, plutonium, tritium) contained in shielded containers. See more. |
|
High Sensitivity Large Volume 15 Liters Calorimeter for Non Destructive Assay |
||
|
LVC-270-15WThe Series 270 is a high sensitive twin cells calorimeter designed for the characterization of nuclear materials and more particularly for the analysis of radioactive wastes and quantification of radioactive elements (e.g. curium, plutonium, tritium) contained in shielded containers. See more. |
|
High Sensitivity Large Volume 25 Liters Tritium Calorimeter for Non Destructive Assay |
||
|
LVC-580The Series 580 is a high sensitive twin cells calorimeter designed for the characterization of nuclear materials and more particularly for the analysis of radioactive wastes and quantification of radioactive elements (e.g. curium, plutonium, tritium) contained in shielded containers. See more. |
|
High Sensitivity Large Volume 60 Liters Tritium Calorimeter for Non Destructive Assay |
||
|
LVC-390The Series 390 is a high sensitive twin cells calorimeter designed for the characterization of nuclear materials and more particularly for the analysis of radioactive wastes and quantification of radioactive elements (e.g. curium, plutonium, tritium) contained in shielded containers. See more. |
|
High Sensitivity Large Volume 90 Liters Tritium Calorimeter for Non Destructive Assay |
||
|
LVC-680The Series 680 is a high sensitive twin cells calorimeter designed for the characterization of nuclear materials and more particularly for the analysis of radioactive wastes and quantification of radioactive elements (e.g. curium, plutonium, tritium) contained in shielded containers. See more. |
|
Calorimètre isotherme de mélange et de réaction (ambiante à 300°C) |
||
|
C80Doté du capteur exclusif "Calvet 3D Sensor Inside" de Setaram, le C80 est le calorimètre le plus puissant disponible à ce jour See more. |
|
Analyseur Thermique de référence (-150°C / 2400°C): DTA, DSC, TGA-DTA/DSC-EGA, TMA |
||
|
La gamme de température la plus étendue du marché (-150°C / 2400°C) La modularité: les différents modules de mesures (ATD, DSC, ATG, TMA) s'adaptent de façon interchangeable sur une même structure Les performances de mesures: tous les modules répondent à des critères uniques de résolution, précision et de sensibilité Le SETSYS Evolution est l'instrument d'analyse thermique de référence dans son domaine de mesure. Il est décliné en 4 versions: -SETSYS Evolution DTA (jusqu'à 2400°C), DSC (jusqu'à 1600°C) -SETSYS Evolution TGA -SETSYS Evolution TGA-DTA/DSC-EGA simultanées -SETSYS Evolution TMA SETSYS Evolution DTA/DSCSETSYS Evolution TGASETSYS Evolution TGA-DTA/DSCSETSYS Evolution TMA |
|
Analyseurs Thermiques à gros volume (ambiant / 2100°C) : Calorimètre, DTA/DSC, TGA-DTA/DSC, TMA |
||
|
La Ligne 96 est une ligne modulaire d'analyseurs thermiques haute température (ambiante / 2100°C) et grand volume. Grand volume d'échantillon: pour analyser des échantillons volumineux, massifs et indissociables (étude de corrosion d'une pièce mécanique ...), pour travailler sur des matériaux hétérogènes (carotte de béton...), pour détecter de très faible variation de masse en ATG (étude de corrosion de tôle métallique...) Modularité: les différents modules (ATD, DSC, ATG, TMA) sont conçus afin de s'adapter à la même structure La Ligne 96 Line se décline ainsi: - MHTC 96 pour la calorimétrie (drop) et les mesures DSC - DTA, DSC 96 - TGA 96 pour des mesures thermogravimetriques et simultanées TGA et DSC/DTA - TMA 96 MHTC 96Ligne 96 DTA / DSCLigne 96 TGALigne 96 TGA - DTA / DSCLigne 96 TMA |
|
Articles
| >>Voir tous les articles |
Brochure
| >>Télécharger |
Inscrivez-vous
Pour un accès complet à la librairie d'application, au catalogue de pièces détachées et aux eNeweltters :
>> Inscription
Déjà enregistré ?
>> Login
>> Inscription
Déjà enregistré ?
>> Login
Nous contacter